Air Inputs and Air Outputs

Plug and play type approved air systems


KPM-Marine Air Input Units have been designed to meet class specifications and all the component parts ABS type approved. They offer the work boat operator high levels of protection, low maintenance costs and air flow performance. Using KPM-Marine arresting technology, air intakes can be reduced in deck footprint and depth allowing the Naval Architect freedom in design. KPM has a massive range to choose from 0.5 to 8 cubic meters per second. Systems are ABS Type approved.


ABS Type approved systems

  • MED/MER dampers
  • Manual DNV Dampers
  • Wide range of fans
  • ATEX systems available
  • 3 vane 0.03 micron mist filters
  • USCG flash back Arrestors
  • Weather closures
  • NOX and SOXs filters
  • Cathodic filters
  • Flood protection
3D drawing of a KPM Strainer

Hydrogen

KPM-Marine are leading with fuel cell and battery compartment air filtration to DNVGL RU-Ship-Pt6-Ch2. The units are designed to ensure that clean air is delivered to the Fuel cell and filters out water, solid particles Sox and Nox to ensure the fuel cell works at optimum.


Combined with ATEX fans, Med dampers, A60 structural fire protection and flash back capability these units are easy to fit and maintain.

DNVGL RU-Ship-Pt6-Ch2

A system for every application


Type 1

Stand alone units

  • A60 fire protection
  • FAN‘s 24,230 400V
  • Mist separation
  • Manual fire flap
  • Med damper
  • Flash back arrestor
  • Diffusers
  • Deck ring

Type 2

Cartridge units

  • A60-30 fire protection
  • No Fan or fan box
  • Mist separation
  • Manual fire flap 
  • Flash back arrestor
  • Mounting ring

Type 3

Flood protected

  • A60-30 fire protection
  • Ducted fan box Fan
  • Mist separation
  • Manual fire flap 
  • Flash back arrestor
  • Flood protected
  • Mounting ring

Type 4

Ducted systems

  • A60 fire protection
  • Fan and mount
  • Mist separation
  • MED damper A60
  • Flash back arrestor
  • Heat bridge ring
  • Stainless Ducting kit
  • Diffuser

Type 5

Fan Cartridge units

  • A60-30 fire protection
  • Internal Fan
  • Mist separation
  • Manual fire flap
  • Flash back arrestor
  • Mounting ring

Type 6

MS breathers

  • A60-30 fire protection
  • Ducted fan box Fan
  • Mist separation
  • Manual fire flap
  • Flash back arrestor
  • Flood protected
  • Deck ring